Skip to content
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
6 changes: 3 additions & 3 deletions .github/workflows/ci.yml
Original file line number Diff line number Diff line change
Expand Up @@ -17,9 +17,9 @@ concurrency:
cancel-in-progress: true

env:
# Pinned commit (buildingsync-measures-gem develop, includes PR #6) of the sibling checkout
# that config/external_measure_repos.yml loads via local_path.
BSYNC_MEASURES_REF: 57eec35b4d1d0c36dca3de2181a0164c35e75bd7
# Pinned commit (buildingsync-measures-gem add-comstock-erv-preset, adds comstock_erv) of the
# sibling checkout that config/external_measure_repos.yml loads via local_path.
BSYNC_MEASURES_REF: 483efc02b5a6c2f1386afd9cae45b72ab4b0a37d

jobs:
unit:
Expand Down
4 changes: 2 additions & 2 deletions BOSS.gemspec
Original file line number Diff line number Diff line change
Expand Up @@ -24,18 +24,18 @@ Gem::Specification.new do |spec|
spec.require_paths = ['lib']

spec.add_dependency 'bundler', '~> 2.4.10'
spec.add_dependency 'httparty', '~> 0.23.2'
spec.add_dependency 'openstudio-common-measures', '~> 0.12.3'
spec.add_dependency 'openstudio-ee', '~> 0.12.5'
spec.add_dependency 'openstudio-extension', '~> 0.9.4'
spec.add_dependency 'openstudio-model-articulation', '~> 0.12.2'
spec.add_dependency 'openstudio-standards', '~> 0.8.2'
spec.add_dependency 'httparty', '~> 0.23.2'
spec.add_dependency 'thor', '~> 1.5.0'

spec.add_development_dependency 'pry', '~> 0.15.2'
spec.add_development_dependency 'rake', '~> 13.0'
spec.add_development_dependency 'rspec', '~> 3.13'
spec.add_development_dependency 'rubocop', '1.50'
spec.add_development_dependency 'rubocop-checkstyle_formatter', '0.6.0'
spec.add_development_dependency 'rubocop-performance', '1.20.0'
spec.add_development_dependency 'pry', '~> 0.15.2'
end
4 changes: 2 additions & 2 deletions Gemfile
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
source 'https://rubygems.org'
source "https://rubygems.org"

gemspec

# gem 'openstudio-extension', path: '../OpenStudio-extension-gem'
#gem 'openstudio-extension', path: '../OpenStudio-extension-gem'
6 changes: 4 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -36,7 +36,7 @@ BuildingSync OpenStudio Simulator (BOSS) takes in BuildingSync files, creates Op
The shipped manifest lives at [config/external_measure_repos.yml](config/external_measure_repos.yml) and is preconfigured with:

- local measure roots: `lib/measures` (first in precedence)
- external repository: comstock (`measures` and `resources/measures`)
- external repository: comstock (`measures` and `resources/measures`), pinned to commit `393de7bf`; later revisions of its recovery measure require the `comstock-typical` gem, which BOSS does not bundle
- local checkout: `buildingsync-measures-gem` (`lib/measures`), expected as a sibling of this repository (`../buildingsync-measures-gem`). It is marked `scenario_only` and is added to `measure_paths` only for baselines that use an HVAC topology. CI pins its commit via `BSYNC_MEASURES_REF` in [.github/workflows/ci.yml](.github/workflows/ci.yml).

Measure path precedence is:
Expand Down Expand Up @@ -67,6 +67,8 @@ Configurations that can produce a topology baseline:

A Ventilation Only (`hvac_ventilation_only`) or Dedicated Outdoor Air System (`hvac_doas`) configuration can be added on top, but only alongside PTAC, PTHP, four-pipe fan coil, or VRF.

A heat recovery or energy recovery ventilator (`OtherHVACSystem` with `Integration` `Integrated with central air distribution`) is applied after sizing with ComStock's `upgrade_hvac_exhaust_air_energy_or_heat_recovery`. When `Integration` is empty it is inferred as central-air integration if every linked delivery is central air distribution. A zone-equipment delivery that holds only fan-based economizer/reset controls and shares its heating and cooling sources with exactly one central-fan delivery is treated as that delivery's controls. Recovery is supported only with packaged rooftop AC/heat pump, warm air furnace, and the two VAV hot water reheat configurations, must link every conditioning delivery, and must serve the whole building. ComStock chooses ERV or HRV from the climate zone; when the audit records an `Energy recovery ventilator`, the gem's `modify_existing_heat_recovery` (`comstock_erv`) then sets ComStock's ERV effectiveness on every heat exchanger. Mixed HRV and ERV records fall back, and audited effectiveness values are not transferred. Stand-alone or local-air recovery falls back.

Recognized but not yet mapped (always fall back): Packaged Rooftop VAV with Electric Reheat, VAV with Electric Reheat, Water Loop Heat Pump, Ground Source Heat Pump, Chilled Beam, and hydronic radiant systems.

BOSS also falls back when:
Expand All @@ -79,7 +81,7 @@ BOSS also falls back when:

On fallback, BOSS uses the `system_type` mapping below with `add_hvac` set to `true`, and logs a warning explaining why.

Integration simulations currently cover the packaged rooftop heat pump; the other configurations are covered by unit specs.
Integration simulations currently cover the packaged rooftop heat pump, with and without recovery (`Example_ASHRAE_L2_Report_l200_erv.xml`, an edited derivative of `Example_ASHRAE_L2_Report.xml`); the other configurations are covered by unit specs.

## OpenStudio Compatibility Version

Expand Down
2 changes: 1 addition & 1 deletion Rakefile
Original file line number Diff line number Diff line change
Expand Up @@ -39,4 +39,4 @@ namespace :measures do
puts "External measure roots (#{dirs.length}):"
dirs.each { |dir| puts " - #{dir}" }
end
end
end
4 changes: 3 additions & 1 deletion config/external_measure_repos.yml
Original file line number Diff line number Diff line change
Expand Up @@ -26,7 +26,9 @@ local_measure_roots:
repos:
- name: comstock
url: https://github.com/NatLabRockies/comstock.git
ref: main
# Pinned: later revisions require the comstock-typical gem in
# upgrade_hvac_exhaust_air_energy_or_heat_recovery, which BOSS does not bundle.
ref: 393de7bf86479537f42ea36c91dd2ec7ae1259ea
measure_roots:
- measures
- resources/measures
Expand Down
85 changes: 85 additions & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_baseline_hvac_flow.mmd
Original file line number Diff line number Diff line change
@@ -0,0 +1,85 @@
flowchart TD
START(["Boss.write_baseline_osw(xml, output, epw, standard)"]) --> BUILD["build_baseline_osw (private)"]
BUILD --> READ["BuildingSyncReader.get_hvac_systems_xml<br/>returns Facility/Systems/HVACSystems"]
READ --> NOSYS{"Planner: HVACSystems present?"}
NOSYS -- no --> FB
NOSYS -- yes --> TPL{"Template supported?<br/>DOE Ref Pre-1980, DOE Ref 1980-2004,<br/>90.1-2004 … 90.1-2019"}
TPL -- no --> FB
TPL -- yes --> SYS

subgraph SELECTOR["HvacTopologySelector.select: one status per Delivery and per OtherHVACSystem"]
SYS{"HVACSystem has Delivery or<br/>OtherHVACSystem records?"}
SYS -- "no (only Principal/PrimaryHVACSystemType)" --> MISS["status: missing_input"]
SYS -- yes --> DUP{"IDs unique?"}
DUP -- no --> R_CONF["status: conflicting_input"]
DUP -- yes --> SPLIT["Deliveries owned by a ventilation record are<br/>judged with that record, not as conditioning"]
SPLIT --> SEL["Each remaining Delivery: follow HeatingSourceID / CoolingSourceID<br/>→ sources → Heating / Cooling / Condenser plants"]
SEL --> REFOK{"References resolve; source IDs<br/>and premises present?"}
REFOK -- "broken / conflicting" --> R_CONF
REFOK -- "field missing" --> MISS
REFOK -- yes --> RULES{"DELIVERY_RULES + NOT_MAPPABLE_DELIVERY"}
RULES -- "one supported rule" --> GUARD{"Must-be-absent elements absent<br/>and guards pass?"}
GUARD -- no --> R_CONF
GUARD -- yes --> MATCH["status: match + measure:<br/>PTAC→hvac_ptac · PTHP→hvac_pthp<br/>RTU AC→hvac_packaged_rooftop_ac<br/>RTU HP→hvac_packaged_rooftop_heat_pump<br/>(supplemental_heating_fuel from HeatPumpBackupSystemFuel)<br/>Pkg VAV HW reheat · VAV HW reheat<br/>Warm air furnace · VRF · 4-pipe FCU"]
RULES -- "gap rule" --> GAP["status: mapping_gap<br/>VAV electric reheat, WLHP, GSHP,<br/>chilled beam, radiant"]
RULES -- "one not-mappable hit" --> NM["status: not_mappable<br/>split DX, split/mini/multi-split HP, SPVAC/SPVHP,<br/>field-assembled DX, 2-pipe fan coil, baseboard/radiator,<br/>heating-only or cooling-only pair, multizone CAV / CAV reheat,<br/>VAV no reheat, unsupported VAV reheat, UFAD, evaporative,<br/>steam/district/solar heat, absorption/district cooling,<br/>air-cooled chiller"]
RULES -- "more than one hit" --> R_CONF
RULES -- "no hit" --> MISS
SPLIT --> OTH["Each OtherHVACSystem"]
OTH --> EQ{"Spot exhaust, humidifier, dehumidifier,<br/>air cleaner, natural ventilation?"}
EQ -- yes --> NM
EQ -- no --> VENT{"VentilationType"}
VENT -- "missing" --> MISS
VENT -- "more than one" --> R_CONF
VENT -- "HRV / ERV / Exhaust only" --> NM
VENT -- "integrated with air distribution" --> INTEG["status: integrated<br/>(linked deliveries judged as conditioning)"]
VENT -- "None" --> ANNOT["status: no_hvac<br/>(explicitly no HVAC, or no separate<br/>ventilation equipment)"]
VENT -- "Supply only / DOAS" --> VCHK{"Links resolve and not shared?<br/>Deliveries unconditioned?<br/>Stand-alone, single-duct CAV?<br/>Guards pass?"}
VCHK -- "broken / shared link, guard fails" --> R_CONF
VCHK -- "deliveries heated or cooled" --> NM
VCHK -- "requirements not met" --> MISS
VCHK -- yes --> VMATCH["match: Supply only → hvac_ventilation_only<br/>DOAS → hvac_doas"]
MATCH --> PREM["Attach premises: record LinkedPremises,<br/>else inherit HVACSystem LinkedPremises"]
VMATCH --> PREM
end

PREM --> PROP
R_CONF --> PROP
GAP --> PROP
NM --> PROP
MISS --> PROP
INTEG --> PROP
ANNOT --> PROP

subgraph PLANNER["BaselineHvacPlanner.plan"]
PROP["Drop results of proposed systems<br/>(exclude_system_ids from a Measure's<br/>AlternativeSystemReplacement / ModifiedSystem)"]
PROP --> ANY{"Any results left?"}
ANY -- yes --> PLAN{"Every result is match?<br/>(any other status falls back,<br/>including integrated and no_hvac)"}
PLAN -- yes --> GROUP["Group by (measure, measure_arguments);<br/>merge premises; split into<br/>conditioning and ventilation"]
GROUP --> CFG{"Configuration checks (all reasons reported together):<br/>exactly 1 conditioning; at most 1 ventilation;<br/>if ventilation, conditioning is zone equipment<br/>(ptac, pthp, four_pipe_fan_coil, vrf)"}
CFG -- pass --> NORM["normalize_premises: Section links covering the building<br/>(Whole building section, or all non-empty sections)<br/>→ treated as Building"]
end

ANY -- no --> FB
PLAN -- no --> FB
CFG -- "any fails" --> FB

subgraph BINDER["HvacTargetBinder.bind (conditioning: given operation; ventilation: always create)"]
NORM --> WB{"Premises all Building / Site / Facility?<br/>(generated geometry has no BuildingSync zone IDs)"}
WB -- yes --> STEP["apply_hvac_topology_to_zone_scope step:<br/>topology_measure, operation create/replace,<br/>zone_scope = all_model_zones, standards_template,<br/>topology_arguments_json (only if measure arguments)"]
end
WB -- "no (zone/space premise)<br/>missing_input" --> FB

STEP --> SIZE["Steps: conditioning → ventilation →<br/>apply_standard_hvac_sizing_and_efficiency(template)"]
SIZE --> TOPO["Plan = :topology"]

TOPO --> OSW1["OSWArgPopulator:<br/>create_typical_building_from_model add_hvac = false<br/>append_step + set_step_argument (per step, no name collision)"]
OSW1 --> DIRS1["measure_paths include scenario_only repos<br/>(buildingsync-measures-gem via local_path ../../buildingsync-measures-gem)"]

FB["Plan = :fallback with reasons"] --> OSW2["create_typical_building_from_model add_hvac = true<br/>log warning per reason:<br/>'Keeping create_typical_building_from_model HVAC: …'"]
OSW2 --> DIRS2["measure_paths exclude scenario_only repos<br/>(sibling gem checkout not required)"]

DIRS1 --> WRITE["Write baseline/in.osw"]
DIRS2 --> WRITE
WRITE --> RUN["Boss.run_baseline_osw → OpenStudio workflow"]
RUN --> CHECK["Integration check (shard 0, non-smoke):<br/>Success, add_hvac=false, PSZ-HP loops w/ NaturalGas<br/>supplemental heat for template, sizing Success"]
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
9 changes: 9 additions & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_0_overview.mmd
Original file line number Diff line number Diff line change
@@ -0,0 +1,9 @@
flowchart LR
A(["Boss.write_baseline_osw<br/><b>start the baseline OSW build</b>"]) --> B["1. Reader<br/>get_hvac_systems_xml<br/><b>read HVACSystems from BuildingSync</b>"]
B --> C["2. HvacTopologySelector<br/>one status per Delivery / OtherHVACSystem<br/><b>classify each HVAC record; match it to a measure</b>"]
C --> D["3. BaselineHvacPlanner<br/>skip proposed systems; all must match;<br/>one conditioning + optional ventilation<br/><b>decide L200 topology or L100 fallback</b>"]
D -- topology --> E["4. HvacTargetBinder<br/>whole-building premises → all model zones<br/><b>apply each measure to all model zones</b>"]
E --> F["5a. L200 OSW: add_hvac = false<br/>+ conditioning, ventilation, sizing steps<br/><b>build the audited HVAC system</b>"]
D -- "fallback to L100" --> G["5b. L100 OSW (generic HVAC workflow):<br/>add_hvac = true<br/>+ one warning per reason<br/><b>fall back to L100 generic HVAC, log why</b>"]
F --> H["6. Write in.osw and run OpenStudio<br/><b>simulate the baseline</b>"]
G --> H
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
41 changes: 41 additions & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_1_selector.mmd
Original file line number Diff line number Diff line change
@@ -0,0 +1,41 @@
flowchart TD
IN(["HVACSystems XML"]) --> SYS{"Each HVACSystem: has Delivery<br/>or OtherHVACSystem records?"}
SYS -- "no (only Principal/PrimaryHVACSystemType)" --> MISS
SYS -- yes --> DUP{"IDs unique?"}
DUP -- no --> R_CONF["conflicting_input"]
DUP -- yes --> SPLIT["Deliveries owned by a ventilation record<br/>are judged with that record, not as conditioning"]
SPLIT --> SEL["Each remaining Delivery: follow HeatingSourceID / CoolingSourceID<br/>→ sources → Heating / Cooling / Condenser plants"]
SEL --> REFOK{"References resolve; source IDs<br/>and premises present?"}
REFOK -- "broken / conflicting" --> R_CONF
REFOK -- "field missing" --> MISS
REFOK -- yes --> RULES{"DELIVERY_RULES + NOT_MAPPABLE_DELIVERY"}
RULES -- "one supported rule" --> GUARD{"Must-be-absent elements absent<br/>and guards pass?"}
GUARD -- no --> R_CONF
GUARD -- yes --> MATCH["match:<br/>PTAC→hvac_ptac · PTHP→hvac_pthp<br/>RTU AC→hvac_packaged_rooftop_ac<br/>RTU HP→hvac_packaged_rooftop_heat_pump<br/>(supplemental_heating_fuel from HeatPumpBackupSystemFuel)<br/>Pkg VAV HW reheat · VAV HW reheat<br/>Warm air furnace · VRF · 4-pipe FCU"]
RULES -- "gap rule" --> GAP["mapping_gap:<br/>VAV electric reheat, WLHP, GSHP,<br/>chilled beam, radiant"]
RULES -- "one not-mappable hit" --> NM["not_mappable:<br/>split DX, split/mini/multi-split HP, SPVAC/SPVHP,<br/>field-assembled DX, 2-pipe fan coil, baseboard/radiator,<br/>heating-only or cooling-only pair, multizone CAV / CAV reheat,<br/>VAV no reheat, unsupported VAV reheat, UFAD, evaporative,<br/>steam/district/solar heat, absorption/district cooling,<br/>air-cooled chiller"]
RULES -- "more than one hit" --> R_CONF
RULES -- "no hit" --> MISS["missing_input"]
SPLIT --> OTH["Each OtherHVACSystem"]
OTH --> EQ{"Spot exhaust, humidifier, dehumidifier,<br/>air cleaner, natural ventilation?"}
EQ -- yes --> NM
EQ -- no --> VENT{"VentilationType"}
VENT -- "missing" --> MISS
VENT -- "more than one" --> R_CONF
VENT -- "HRV / ERV / Exhaust only" --> NM
VENT -- "integrated with air distribution" --> INTEG["integrated<br/>(linked deliveries judged as conditioning)"]
VENT -- "None" --> ANNOT["no_hvac<br/>(explicitly no HVAC, or no separate<br/>ventilation equipment)"]
VENT -- "Supply only / DOAS" --> VCHK{"Links resolve and not shared?<br/>Deliveries unconditioned?<br/>Stand-alone, single-duct CAV?<br/>Guards pass?"}
VCHK -- "broken / shared link, guard fails" --> R_CONF
VCHK -- "deliveries heated or cooled" --> NM
VCHK -- "requirements not met" --> MISS
VCHK -- yes --> VMATCH["match: Supply only → hvac_ventilation_only<br/>DOAS → hvac_doas"]
MATCH --> PREM["Attach premises: own LinkedPremises,<br/>else inherit HVACSystem's"]
VMATCH --> PREM
PREM --> OUT(["Results → Planner"])
R_CONF --> OUT
GAP --> OUT
NM --> OUT
MISS --> OUT
INTEG --> OUT
ANNOT --> OUT
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
21 changes: 21 additions & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_2_planner.mmd
Original file line number Diff line number Diff line change
@@ -0,0 +1,21 @@
flowchart TD
IN(["BaselineHvacPlanner.plan(hvac_systems, template,<br/>exclude_system_ids = proposed systems)"]) --> NOSYS{"HVACSystems present?"}
NOSYS -- no --> FB
NOSYS -- yes --> TPL{"Template supported?<br/>DOE Ref Pre-1980, DOE Ref 1980-2004,<br/>90.1-2004 … 90.1-2019"}
TPL -- no --> FB
TPL -- yes --> SELECT["Run HvacTopologySelector"]
SELECT --> PROP["Drop results of proposed systems<br/>(named by a Measure's AlternativeSystemReplacement<br/>or ModifiedSystem; computed in boss.rb)"]
PROP --> ANY{"Any results left?"}
ANY -- no --> FB
ANY -- yes --> ALL{"Every result is match?<br/>(any other status falls back,<br/>including integrated and no_hvac)"}
ALL -- no --> FB
ALL -- yes --> GROUP["Group by (measure, measure_arguments);<br/>merge premises; split into<br/>conditioning and ventilation"]
GROUP --> CFG{"Configuration checks (all reasons reported together):<br/>exactly 1 conditioning; at most 1 ventilation;<br/>if ventilation, conditioning is zone equipment<br/>(ptac, pthp, four_pipe_fan_coil, vrf)"}
CFG -- "any fails" --> FB
CFG -- pass --> NORM["normalize_premises: Section links covering the building<br/>(Whole building, or all non-empty sections) → Building"]
NORM --> BIND["HvacTargetBinder.bind<br/>conditioning: given operation (create/replace)<br/>ventilation: always create"]
BIND --> OK{"All bindings bound?"}
OK -- no --> FB
OK -- yes --> SIZE["Steps: conditioning → ventilation →<br/>apply_standard_hvac_sizing_and_efficiency(template)"]
SIZE --> TOPO(["Plan :topology with steps"])
FB(["Plan :fallback with reason messages"])
1 change: 1 addition & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_2_planner.svg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
13 changes: 13 additions & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_3_binder.mmd
Original file line number Diff line number Diff line change
@@ -0,0 +1,13 @@
flowchart TD
IN(["HvacTargetBinder.bind(result, operation, standards_template, zone_names)"]) --> T{"Result is match?<br/>(operation and template already<br/>validated by the planner)"}
T -- no --> MI["Return the result's status and messages"]
T -- yes --> Z{"zone_names given?"}
Z -- yes --> EX["zone_scope = explicit_zone_names"]
Z -- no --> WB{"Premises present and all Building / Site / Facility?<br/>(generated geometry has no BuildingSync zone IDs)"}
WB -- no --> MI2["missing_input: only whole-building<br/>premises can bind"]
MI2 --> FB
WB -- yes --> ALLZ["zone_scope = all_model_zones"]
EX --> STEP
ALLZ --> STEP["Step apply_hvac_topology_to_zone_scope:<br/>topology_measure, operation (create/replace),<br/>zone_scope, standards_template,<br/>topology_arguments_json (only if measure arguments)"]
STEP --> OUT(["Step → Planner"])
MI --> FB(["Planner falls back"])
1 change: 1 addition & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_3_binder.svg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
15 changes: 15 additions & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_4_osw.mmd
Original file line number Diff line number Diff line change
@@ -0,0 +1,15 @@
flowchart TD
P{"Plan kind"} -- topology --> T1["create_typical_building_from_model<br/>add_hvac = false"]
T1 --> T2["OSWArgPopulator.append_step for each planned step<br/>set_step_argument per step (no name collision)"]
T2 --> T3["Steps in order: conditioning → ventilation → sizing<br/>measure_paths include scenario_only repos<br/>buildingsync-measures-gem via local_path<br/>../../buildingsync-measures-gem"]
P -- fallback --> F1["create_typical_building_from_model<br/>add_hvac = true"]
F1 --> F2["Log warning per reason:<br/>'Keeping create_typical_building_from_model HVAC: …'"]
F2 --> F3["measure_paths exclude scenario_only repos<br/>(sibling checkout not required)"]
T3 --> W["Write baseline/in.osw"]
F3 --> W
W --> R["Boss.run_baseline_osw → OpenStudio"]
R --> C["Integration check (shard 0, non-smoke):<br/>Success, add_hvac=false, PSZ-HP loops with NaturalGas<br/>supplemental heat for template, sizing Success"]
subgraph CI["CI (.github/workflows/ci.yml)"]
C1["Checkout BOSS into BOSS/"] --> C2["Checkout buildingsync-measures-gem<br/>at BSYNC_MEASURES_REF"]
end
C2 -.-> T3
1 change: 1 addition & 0 deletions docs/L200-baseline-HVAC-flowcharts/l200_flow_4_osw.svg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Loading